SYSTEMS/MASONRY
The connection of a masonry wall and a concrete foundation is shown in Figure 4.2.26 (Brand). In
this detail, the outer face of the backup wall and the outer face of the foundation wall are in the
same plane and support the air barrier. The insulation below the termination of the brick veneer
must be protected, for example with a cement coating.
ACCEPTABLE
Plaster
coating
Figure 4.2.26 Wall / Foundation Connection (Brand)