PROVIDE WALL RECESS FOR PLACEMENT
OF DRIVE MECHANISM & ACCESS PANEL
FOR SERVICING IN THE ADJACENT SPACE
(CANTILEVERED PLATFORM LIFTS)
WALL MOUNTED CONTROLS
MINIMUM 32" CLEAR
FOR OCCUPANT PREFERRED
MINIMUM* CLEAR AREA ON
OPENING W/ INTERLOCKING
(MAXIMUM 54" FROM LOWEST
LIFT FOR WHEELED CHAIR
GATE
IS 3'-0" x 5'-0"
LEVEL & 9" MINIMUM FROM
HIGHEST LEVEL)
IF A PIT IS REQUIRED TO
CONTINUOUS RAILING AT 34" HIGH
AVOID RAMP CONDITION
MOUNTED TO PLATFORM
DEPTH COULD VARY FROM
(THE INSIDE NET PLATFORM AREA SHALL
NOT EXCEED 18 SQUARE FEET)*
4-8 INCHES DEPENDING ON
MINIMUM 32" CLEAR OPENING
MANUFACTURER.
W/ INTERLOCKING GATE
(INITIAL OR FUTURE ACCESS
TO JUDGE'S BENCH)
PIT CONDITION PREFERRED, BUT
FOR PLATFORM SYSTEM BASE
LIFT ENCLOSURE TOP 42"
ASSEMBLY AT FLOOR LEVEL
ABOVE HIGHEST LANDING
PROVIDE 1:12 RAMP TO TOP
OF LIFT PLATFORM IN
LOWEST ELEVATION.
MINIMUM 42" CLEAR OPENING
W/ INTERLOCKING GATE
(AMBULATORY ENTRANCE)
30" CLEAR OPENING W/
INTERLOCKING GATE.
* CLEAR OF ANY
NOTE:
CONTROL STANCHION
MOUNTED ON THE
LOCATE ELECTRICAL PANELS
PLATFORM.
& HYDRAULIC PUMPS IN
ELECTRICAL CLOSET (DO
(COUNTER ABOVE)
NOT LOCATE WHERE A
FLOOR ACCESS PANEL IS
REQUIRED.)