U.S. Courts Design Guide
Table 7.4
Heating, Ventilating, and Air Conditioning (HVAC) and Lighting
HVAC
LIGHTING
TEMP
TYPE:
(degrees Fahrenheit)
HUMIDITY
I = Indirect
(degrees Celsius)
(Perc.)
D = Direct
CONTROL
S
W
S
W
GENERAL
LEVEL
SPACES
REMARKS
(FTC) (lx)
JURY ASSEMBLY AREA
(1) Outdoor temperature
equal to ASHRAE 1%
design dry bulb and
Check-in
74-76
70-74
45-55
25-35
20
8
80-85
30
D
Q
Q
coincident wet bulb.
(23.3-24.4)
(21.1-23.3)
(9.45)
(320)
(1)
(2)
(3)
(4)
(2) Outdoor temperature
Jury Clerk's Office
8
80-85
50
D
Q
equal to ASHRAE 99%
(540)
design dry bulb.
Coat Closet
(3) Outdoor air at design
temperature.
(4) Outdoor temperature is
Juror's Toilets
ASHRAE 97.5%.
Service Unit
30
D
Q
(320)
Vending Area
D
Q
Juror Lounge
45-55
25-35
8
80-85
D
D
Q
(3)
(4)
Assembly Area
10
80-85
D
Q
Q
Equipment Storage
20
(215)
Supplies Storage
TRIAL JURY SUITE
Soundlock Entry
74-76
70-74
45-55
25-35
20
8
80-85
20-30
D
Q
(23.3-24.4)
(21.1-23.3)
(9.45)
(215-320)
(1)
(2)
(3)
(4)
Jurors' Toilets
Coat Closet
7-16
12/19/97