Chapter 6: Ancillary Facilities
Trim and Moldings
Use AWI premium-grade, solid hardwood, decorative moldings, as dictated
by the design or existing building decor conditions.
Decorative moldings include, but are not limited to, base, chair rail, crown,
panel molds, and other moldings as required.
Ceiling
Use suspended acoustical tile and/or gypsum wallboard finishes, as dictated
by the design or existing building decor conditions.
Provide other ceiling elements, such as soffits, perimeter coves, recesses, and
reveals as required to integrate heating, ventilating, and air conditioning
(HVAC) and lighting into a harmonious design.
Provide acoustical treatment, material, or detail as required to meet noise
criteria.
Floor Covering
Use 42-ounce (1.19 kg) face-weight, synthetic (nylon or equal), commercial-
grade carpet over a synthetic fiber cushion.
Service Unit
Provide a residential-type service unit consisting of AWI custom-grade,
hardwood veneer cabinets with solid hardwood doors, door and cabinet
frames (base and wall cabinets). The unit should be 72 inches (1825 mm)
long, and consist of a decorative plastic laminate countertop.
Provide an 18/8 brushed stainless steel sink, 22 inches (575 mm) by 25 inches
(625 mm) by 6 inches (150 mm) deep, and a single-lever faucet.
Furniture/Fixtures
A wall-mounted writing/display/projection surface unit should be provided for
presentations. A conference table must be provided. A minimum of 30 linear inches
(775 mm) of table surface must be provided for each anticipated occupant. Typical
seating consists of movable, swivel armchairs.