SHELL & CORE BACK-UP
MINIMAL FAADE RENOVATION
Prepared: 1 August 2003
Shell & Core
Reference Date: 10/1/2003
"Great Society" Mid Rise Office Building
Area: 265,200 GSF
No Market
Market
Total Market
Comparable
Description
Quantity
Unit
Rate
Equivalent
Equivalent
(Premium $)
E
EQUIPMENT & FURNISHINGS
E10
Equipment
E1009 Commercial / Institutional Equipment
Not Applicable
-
Total E10 Equipment
E20
Furnishings
E2010 Fixed Furnishings & Casework
180 LF
.92
,206
Plastic laminate counter, 24" wide
1 EA
,018.31
,018
Entrance reception counter in main lobby
500 SF
.39
,695
Allow for mail room furnishings
25,919
Total E20 Furnishings
F
SPECIAL CONSTR & DEMOLITION
F20
Building Demolition
F2010 Building Elements Demolition
TV slab and punch openings for data/telecom
265,200 GSF
,604
Remove drywall at interior of perimeter wall
72,402 SF
||content||
.35
,743
Remove existing curtainwall
36,750 SF
.47
7,773
Remove existing punched windows
36,750 SF
.39
8,083
Gut existing (drywall) ceiling finishes from all
core & shell areas
248,346 SF
3,578
Gut existing floor finishes from all core & shell
areas (no asbestos)
46,147 SF
,455
Gut existing wall finishes from all core & shell
areas
102,574 SF
,283
Gut existing elevator cab finishes
5 EA
8.58
,043
Demolish existing domestic cold water system,
existing domestic hot water system, all sanitary
piping downstream of the main riser, existing
drinking fountains
265,200 SF
,604
Demolish existing 4-pipe heating & air
conditioning system in its entirety
265,200 SF
||content||
.08
6,416
Demolish existing vertically zoned, constant
volume system including (8) air handlers and
associated ductwork
265,200 SF
3,208
265,200 SF
,604
Demolish existing fire protection sprinkler
systems, including fire pump
265,200 SF
,432
Demolish complete power riser system w/closet
265,200 SF
4,036
Demolish wiring to parabolic fixture every 80
sf, perimeter convenience outlets, mechanical
wiring, core and lobby power and lighting
fitout, utility space power and lighting fitout
265,200 SF
4,036
Page 8