DOE-2 Energy Modeling Summary - Office Building
Page 15 of 21
F. LEEDTM ENERGY ANALYSIS
A LEED reference case was developed to determine the number of credits earned by the
Baseline GSA buildings
SUMMARY OF DIFFERENCES BETWEEN BASELINE CASE AND LEEDTM REFERENCE CASE
GSA Baseline
LEED Reference Case (ASHRAE 90.1)
Windows - Full Facade Renovation Only:
Windows - Full Facade Renovation Only:
All Floors
Floors 1 & 2:
C 1" Insulating glass (2 - 1/4" panes with
C 1" Insulating glass (2 - 1/4" panes with
" air space), low-E
" air space), low-E
C Ucenter of glass
C Ucenter of glass
0.32
0.32
C Visible transmittance
C Visible transmittance
57%
57%
C Shading coefficient
C Shading coefficient
0.35
0.35
C With thermally broken aluminum frame
C With thermally broken aluminum frame
C Ufenestration
C Ufenestration
0.43
0.43
Floors 3-9:
C Shading coefficient
0.45
C Visible transmittance
78%
C Ufenestation
0.57
Windows - Minimal Facade Renovation
Windows - Minimal Facade Renovation
Only:
Only:
All Floors
All Floors
C 1" Insulating glass (2 - 1/4" panes with
C 1" Insulating glass (2 - 1/4" panes with
" air space), low-E
" air space), low-E
C Ucenter of glass
C Ucenter of glass
0.32
0.32
C Visible transmittance
C Visible transmittance
57%
57%
C Shading coefficient
C Shading coefficient
0.35
0.35
C With thermally broken aluminum frame
C With thermally broken aluminum frame
C Ufenestration
C Ufenestration
0.43
0.43
APPENDIX J - GSA LEED COST STUDY